Case Study - Meat & Food Processing Facilities
Meat Processing Facility
Problem:
- This site was producing 300-400 cubic meters of waste (6 litres per second) into their effluent ponds daily
- The smell was an issue, the jets on the irrigation system from the pond were blocking and the pond was crusting. The compliance requirement is to reduce the output of BOD by 80%.
- The site had trialled Molasses: Reduction in BOD was 70%
Solution:
- Bio-Zyme Industrial daily pumped into line to effluent pond resulted in:
- Reduction of BOD output of 90 - 95%
- Eliminated smell
- Jets all clear on irrigation system
- No crusting on pond
- No build-up on pipes
- Have continued using Bio-Zyme Industrial in this manner since March 2008. Currently also using
Multipurpose to clean floors of the factory.
Food Processing Facility
Problem:
- Auckland City Council Compliance level is 200mg/l of oil and grease output
- Council test on site @ 856mg/l oil and grease output
- Risk of a fine or being shut down till work was completed to be compliant
Solution:
- Bio-Zyme dose pump installed onto grease converter to pump 100ml every 24hrs of Bio-Zyme Industrial
- Council test on site @32mg/l oil and grease output (14 days later).
- Client has been using Bio-Zyme Industrial in this manner and would highly recommend the product.
- Have continued using Bio-Zyme since July 2017
Download Here
Case Study - By Products & Seafood Processing Facilities
By Products Processing Facility
Problem:
- Smell issues, Council complaints and media reports.
- 33,000L underground Bio Filter (water sprayed over bark) smell was excessive
Solution:
- Visit to assess the problem 27th July
- 28th July Order 200L + 8 x 20L Bio-Zyme Industrial. Used the 200 litres as shock dose then administered through spraying system
- 8th October rung client using 2 x 20L per week through the spraying system
- No smell, no complaints from Council or Media. Happy with results
Have continued using Bio-Zyme and reduced the amount being used since June 2015
Seafood Processing Facility
Waste Water Treatment System installed
Problem:
- System failing due to odour, causing the Company to get the system pumped out by liquid waste contractor every week sometimes twice a week.
Cause: Using caustic and quat based cleaning products 7 times a day and emptying down toilets when finished to waste water system.
Solution:
- Using Bio-Zyme Cleaner at 30ml/per litre to clean amenities empty down toilets when finished to waste water system
- Using 1L Bio-Zyme Industrial down toilet straight to wastewater system for shock treatment
- Bio-Zyme enhanced the bacteria to become healthy which eliminated the smell and the need for weekly clean outs. Notable difference in odour within 3 days.
Have continued using Bio-Zyme & reduced daily dose. Since May 2019.
Download Here
Case Study - Dairy Farm
Dairy Farm
Problem:
- Farm with a herd of 500 cows and effluent being discharged into a 120-180 day storage pond.
Had odours and pond crusting - weeping walls blocking.
Solution:
- Primed pond with 40 litres Bio-Zyme Industrial then followed up with 1 litre per day pouring down drains of cowshed to effluent pond.
- Resulted in reducing odour, crusting and solids in pond. Helps weeping walls work more efficiently and keeps the irrigation jets clean and clear of debris.
- After effluent was irrigated on paddocks the grass was more palatable for the cows and livestock, while still being cost-effective.
- Have continued using Bio-Zyme since Dec 2018
Download Here
Case Study - Southland Farm Milking 1000 Cows
Southland Farm Milking 1000 Cows
Site Visit
24th September 2018
Pre Treatment Findings
- Odour from Pond
- Crusting on pond 1.45 mtrs
- Aerator (stirrer) used 4.5 hours per day
- Solids being dumped on paddock when emptied
Treatment Plan
- Shock dose pond with 20L Bio-Zyme Industrial
- Pour 2 litres Bio-Zyme Industrial down drain in pit of rotary cowshed daily
Site Visit
23rd October 2018
Findings after 1 month
- Minimum Odour of Pond
- Crusting on pond 700mm
- Aerator (stirrer) used 1.5 hours per day since 3rd October
- Liquefied solids more noticeable
Site Visit
24th November 2018
Findings after 2 months
- Minimum Odour of Pond
- Crusting on Pond Nil all liquid
- Aerator (stirrer) not used at all since 23rd October
Outcome - Positives
- Minimal to no odour in Pond
- Grass more palatable for Cows
- Cows ate 100% of allocation
- No Smell when irrigating
- Irrigation Jets clean no blockages
- Grazing rotation available earlier than previous rotations
- Smell reduced significantly in centre of Rotary shed and drains
- Savings in power and maintenance due to not using aerator (stirrer)
- Bio-Zyme 20L Industrial Cleaner
- Oxidation Pond Test
- Use rate: 1L Industrial daily per 500 cows
Download Here
Case Study - Fast Food, Dining in and Takeaway
Fast Food, Dining in and Takeaway
GT3000 Grease Trap with Bio-Zyme | Site 1 & Site 2 are the exactly same size. Site 2 has 20% less sales than site 1. | Both sites opened 3 years ago.
Tests: September 2022 & September 2023
Download Here
Case Study - Polytec
Polytec
Polytec Facility - South Island with approximately 2000 staff and students on site.
Hygiene Servicing Company had a contract to service sanitary units, contract for 3 years. Units were serviced fortnightly, monthly and 6 weekly depending on perceived usage. Now cleaners on site servicing Hygiene Units as required.
Over the last 8 months including 5 weeks of Covid-19 lock down the Polytec have purchased 4 cartons (100 cartridges per carton). With the addition of holidays throughout the year including December and January, the Polytec have done the following calculations.
After the initial set up of a one-off purchase of the Hygiene Units
- 1st year's savings was 72.6%
- 2nd year's savings was 81.9%
- 3rd year's savings was 81.9%
Polytec usually sign a 3 year contract for hygiene servicing. After bringing this service in-house they have saved 78.8% over a 3 year term.
Download Here